Vacuum Chamber Leak Detection System for Lithium Battery
Vacuum Chamber Leak Detection System for Lithium Battery
Product advantages
Product Details
Introduction of the Vacuum Chamber Leak Detection System
The vacuum acuum leak detection systems are used for the rapid and accurate detection of helium or hydrogen by vacuum helium injection, suction lance, helium hood and back pressure detection methods for industrial testing in a variety of demanding and harsh environments.
Parameters of the Vaccum Chamber Leak Detection System
Automatic Vacuum Chamber Helium Leak Detection System for Lithium Battery | ||
Workpiece | Metal bipolar plates, Membrane electrode | |
Product Size | 4500*2000*2000mm/Customized | |
Power | 20KW | |
Weight | 3000KG/Depends on real item | |
Leak detector opening detecting pressure | ≤30pa | |
Workpiece Evacuation pressure | ≤2000pa | |
Helium leak detector parameters | Display ranges | 1.0*10-3~10-13 Pa.m3/s |
| Minimum detectable leakage rate | 5*10-13 Pa.m3/s |
| Response Time | <1S |
Leak rate control setting | Set up on the system according to your process requirements | |
Overkill Rate | ≤1% | |
Leakage rate | 0 | |
Equipment failure rate | ≤1% | |
Yield rate | ≥99.9% | |
Leak detection tempo | ≥3PPM | |
Motro Power | 600 W | |
Ultimate pressure | 1000 Pa | |
Performance of the Vacuum Chamber Leak Detection System
1. The size of Accept your customized sizes of vacuum chamber, equipment size and layout
2. High-end configuration, standardized design and production, and stable and reliable performance;
3. The multi-chamber linkage design can realize flexible production, and the production rhythm can reach 6PPM-20PPM per unit;
Applications
Power switchgear, ring main unit, pole top switch, power castings.