Wide Range Flow Rate Pressure Decay Leak Detector
Wide Range Flow Rate Pressure Decay Leak Detector
Product advantages
Product Details
Introduction of Flow Rate Pressure Decay:
The flow rate pressure decay leak detector is equipped with a special pneumatic valve group with low leakage and reliable operation and a leak detection sensor with high sensitivity and high pressure resistance, which has extremely high test resolution and sensitivity.
Parameters of Flow Rate Airghtness Pressure Decay
|
Product Name |
Flow Rate Pressure Decay |
|||
|---|---|---|---|---|
|
Flow Sensor |
Display Precision |
The value can be set to 0 to 4 decimal places |
||
|
Sensor Range |
LC103 (V5) |
30mL/min~1000mL/min (optional) |
||
|
|
LC101 (V6) |
15mL/min~1000mL /min (optional) |
||
|
Sensor Error |
±3%F.S.(optional) |
|
|
|
|
Direct Pressure |
Display Precision |
The value can be set to 0 to 4 decimal places |
||
|
Recommended Test Pressure Range |
LC103 (V5) |
Mechanical Pressure Regulating |
10~600kPa (Optional) |
|
|
LC101(V6) |
Mechanical Pressure Regulating |
10~600kPa (Optional |
||
|
Sensor Error |
±0.1%FS. |
|
|
|
|
Display Unit |
Test Pressure |
kPa,Mpa,kg/cm2,psi,mbar.bar, Torr,mmH,O,mmHg |
||
|
Leakage |
mL/s,mL/min,L/min,Lh,m3/h,Pa/min,g/h,SCCM |
|||
|
Parameter Program Number |
64 groups(1~64) |
|||
|
Test Beat Setting |
0~3600 seconds |
|||
|
Power Supply |
AC220V±10%, 50Hz |
|||
|
Test Pressure Source |
Clean, Dry, Adequate flow, no less than 500KPa and 100KPa above the test pressure source |
|||
|
Overall Diamensions |
Standard V5 |
330mm*222mm*448mm |
||
|
Standard V6 |
321mm*205mm*560mm |
|||
|
Weight |
About 15kg |
|||
Applications
Helium leak detector is also used in the medical sector for various applications. Some of the most common medical applications of helium leak detection include:
Leak testing of medical gas systems, including oxygen, nitrogen, and carbon dioxide systems
Testing of vacuum systems used in medical equipment, such as MRI machines
Leak testing of anesthesia machines
Leak testing of sterilization equipment
Helium leak detector is preferred in medical applications because it is non-toxic, non-reactive, and does not leave any residue. This ensures the safety and purity of medical gases and equipment, which is critical for patient safety.
Support and Services:
Installation Assistance: Guidance through the setup process to ensure your leak detector is installed correctly and functioning optimally right from the start.
Operational Training: Comprehensive training sessions for operators to become proficient in using the device, understanding its features, and interpreting results accurately.
Software Updates: Regular updates to the device's software to ensure you have access to the latest features, improvements, and security enhancements.
Repair Services: In the event of a malfunction, we offer repair services to restore your device to its full functionality as quickly as possible.
Parts Replacement: Access to genuine replacement parts to ensure the longevity and reliability of your helium leak detector.
Technical Documentation: Provision of detailed documentation, including user manuals, technical specifications, and troubleshooting guides to support the use of your device.

Product recommend
Application Case
To download the complete product brochure, please fill in the following information.
To download the full solution, please fill in the following information.