Laboratory Analytical Instruments
Mass Spectrometry Instruments
Picture Name
Picture Name
Picture Name
Picture Name
Picture Name
Picture Name
Picture Name
Picture Name
Picture Name
Picture Name
Picture Name
Picture Name
Picture Name
Picture Name

GM6100 High Sensitivity Gas Chromatography-Mass Spectrometry (GC-MS)

  • GM6100 High Sensitivity Gas Chromatography-Mass Spectrometry (GC-MS)
GM6100 High Sensitivity Gas Chromatography-Mass Spectrometry (GC-MS)
+
GM6100 High Sensitivity Gas Chromatography-Mass Spectrometry (GC-MS)
+
  • GM6100 High Sensitivity Gas Chromatography-Mass Spectrometry (GC-MS)

GM6100 High Sensitivity Gas Chromatography-Mass Spectrometry (GC-MS)


Wayeal GM6100 Gas Chromatography-Mass Spectrometry (GC-MS) Systems integrates the upgraded GC6100 gas chromatograph with a high-performance mass spectrometer detector, creating a precise and intelligent gas chromatography-mass spectromet system. Through advanced control systems and intelligent algorithms, it ensures the continuity and stability of the experimental process.

Product advantages

[object Object],[object Object] [object Object],[object Object]

Precise Analysis System

[object Object],[object Object] [object Object],[object Object]

Smart Experience

[object Object],[object Object] [object Object],[object Object]

Comprehensive Service

Product Details

Introduction of Gas Chromatography-Mass Spectrometry (GC-MS) Systems

Wayeal GM6100 Gas Chromatography-Mass Spectrometry (GC-MS) Systems integrates the upgraded GC6100  gas chromatograph with a high-performance mass spectrometer detector, creating a precise and intelligent gas chromatography-mass spectromet system. Through advanced control systems and intelligent algorithms, it ensures the continuity and stability of the experimental process.

Technical Specification of GM6100 Gas Chromatography-Mass Spectrometry (GC-MS) 

 

Working Conditions  
Power supply 220V ±10%, 50Hz ±2%
Ambient Temperature 5°C to 40°C
Relative Humidity 20% to 85%
GC Injection Port  
Injection port Split/Splitless
Maximum operating temperature 450°C
Control precision 0.001 psi
Control range 0–100 psi
Maximum split ratio 12,500:1
Optional carrier gases N₂, H₂, He, Ar
Flow rate range N₂:0–500 mL/min;H₂:0–1250 mL/min;He:0–1250 mL/min
Oven  
Temperature range Above ambient temperature +4°C to 450°C
Programmable temperature ramps 32 steps/33 platforms
Maximum heating rate ≥75°C/min (up to 120°C/min optional)
Column cooling time (22°C ambient) From 450°C to 50°C in less than 5 minutes
Maximum program run time 9999.99 minutes
Mass Spectrometry Detector  
Ion Source  
Ionization energy 15-250eV
Ion source temperature 150-350℃
Transfer line temperature 100-350℃
Quadrupole Mass Filter  
Mass range 0.5amu-1250 amu
Mass stability < 0.10 amu/48 hrs
Acquisition mode scan,SIM,scan and SIM
Ion Detector  
Maximum scan speed 20000amu/ s
Dynamic range 106
Fore pump pumping speed ≥4m³/h
Turbo molecular pump pumping speed ≥250L/s
Autosampler  
Sampler capacity 16 positions
Solvent bottle positions 2
Waste bottle positions 1
Syringe cleaning modes Standalone, pre-injection, post-injection
Injection Volume 0.1-5ml
Software Smart Lab CDS GC-MS Workstation

Product recommend

Application Case

To download the complete product brochure, please fill in the following information.

Privacy Terms
Security verification
online message
%{tishi_zhanwei}%

To download the full solution, please fill in the following information.

Privacy Terms
Security verification
online message
%{tishi_zhanwei}%