LCMS-TQ9200 Liquid Chromatography-Mass Spectrometry (LC-MS/MS) System

  • LCMS-TQ9200 Liquid Chromatography-Mass Spectrometry (LC-MS/MS) System
LCMS-TQ9200 Liquid Chromatography-Mass Spectrometry (LC-MS/MS) System
+
LCMS-TQ9200 Liquid Chromatography-Mass Spectrometry (LC-MS/MS) System
+
  • LCMS-TQ9200 Liquid Chromatography-Mass Spectrometry (LC-MS/MS) System

LCMS-TQ9200 Liquid Chromatography-Mass Spectrometry (LC-MS/MS) System


The system consists of the LC3600 ultra-high-performance liquid chromatograph and the TQ9200 triple quadrupole mass spectrometer. It incorporates core technologies such as an ultra-high-pressure direct-drive pump, ultra-high-pressure needle-in-flowpath lossless injection, an actively preheated column oven, a highly stable EI source, a high-durability vacuum interface, high-efficiency ion transfer lenses, and a tandem quadrupole high-stability drive system. These innovations collectively deliver stable, sensitive, and durable instrument performance.

Product advantages

[object Object],[object Object] [object Object],[object Object]

More stable

[object Object],[object Object] [object Object],[object Object]

More sensitive

[object Object],[object Object] [object Object],[object Object]

More durable

Product Details

Introduction of LC-MS/MS

The system consists of the LC3600 ultra-high-performance liquid chromatograph and the TQ9200 triple quadrupole mass spectrometer. It incorporates core technologies such as an ultra-high-pressure direct-drive pump, ultra-high-pressure needle-in-flowpath lossless injection, an actively preheated column oven, a highly stable EI source, a high-durability vacuum interface, high-efficiency ion transfer lenses, and a tandem quadrupole high-stability drive system. These innovations collectively deliver stable, sensitive, and durable instrument performance.

Technical Parameters of TQ9200

Working conditions

 

Working power supply

220V±22V, 50Hz±0.5Hz

Ambient temperature

15-30°C

Relative humidity

not more than 80%

UHPLC

 

Pump drive mode

linear motor pump

Gradient mode

binary (4-waysolvent)

Flow rate setting range

0.001-2.000mL/min

Flow rate setting increment

0.001mL/min

Maximumoperating pressure

150MPa

Degassing

5-channel online degassing

Autosampler

 

Maximumwithstand pressure

150MPa

Sampling volume range

0.1-20.0μL (50μL optional)

Linearity

R≥0.9999

Cross-contamination

<0.004 %

Number of samples

108 (2*54,2 ml), supports 96 shallow well plate, 96 deep well plate, 384 well plate

Temperature setting range

4.0~40.0 ℃ (optional refrigeration)

Temperature stability

±2 ℃

Feed rate

12s

Column temperaturechamber

 

Temperature setting range

20.0-90.0 ℃

Temperature stability

±0.02 ℃/h

Temperature setting value error

± 0.1 ℃

Triple quadrupole mass spectrometer

 

Mass analysis range

5-1250 Da(Standard); 5-2000Da(Optional)

Scanning speed

12000 Da/s

Mass resolution

0.6-0.8 Da (609 mass peaks)

Linearity range

≥1E4

Mass accuracy

0.1 Da

Massstability

0.1 Da/24h

Limit of detection (rifampicin)

0.1pg

Sensitivity

S:N >20w:1 on a 1pg Risperdal column

System indicators

 

Qualitative reproducibility

RSD≤5%

Quantitative reproducibility

RSD≤5%

Product recommend

Application Case

To download the complete product brochure, please fill in the following information.

Privacy Terms
Security verification
online message
%{tishi_zhanwei}%

To download the full solution, please fill in the following information.

Privacy Terms
Security verification
online message
%{tishi_zhanwei}%